The 23:00 lockdown -> 05:00 unlock cycle exposed three live bugs: a visible
console-text flash before the screen went black (blank_console only ran once
systemctl stop lightdm.service fully returned, leaving a gap), DP-0 needing a
manual xrandr/replug after wake, and the morning alarm firing only 6h after a
late lockdown entry instead of waiting a full 8h.
- Blank the console continuously in a background poller for the whole GUI
teardown instead of a single after-the-fact call.
- Retry autorandr --change against a saved profile after lightdm restarts.
- Stamp lockdown-entry time and gate the alarm on entry + 8h, decoupled from
the console/GUI-restore idempotency so it can fire on a later staggered
trigger instead of only the first one.
- Add DRY_RUN NOTE banners so a clean dry run is never mistaken for proof the
console-blank and autorandr fixes work for real (they need a live cycle).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01S4YWZhDcEUMUi8cyw9AzTR