Same config move as crdt-sync (ignore-paths, init-hook, the three implicit-booleaness disables the reference repos carry). The gate stays at 8.0 for now: LockConfig's 35-field record and the two fail-open guards in the recovery loop are still open. Everything else pylint had left on source is gone. The optional python-xlib dependency is loaded through one importlib helper instead of two function-scope import statements, keeping the "not installed" arm reachable for branch coverage; RecoveryLoop and LockWindow hold their collaborator bundles rather than unpacking them into a second set of attributes; the claim types are imported from _claims, where they are defined, so _arbiter no longer needs an export list that mirrored the package's; runtime imports sit above TYPE_CHECKING blocks; the RandR Protocol stubs say which Xlib call they mirror. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01HHCbkJWXHjtTUaqvnHRAqA
148 lines
5.1 KiB
Python
148 lines
5.1 KiB
Python
# Copyright (c) 2026 Krzysztof Rudnicki
|
|
"""Enumerate X11 outputs and tell live ones apart from dark ones.
|
|
|
|
The distinction this module exists to make is ``connected`` versus **live**.
|
|
On 2026-07-25 a monitor came up ``connected``, with a valid EDID, and no
|
|
mode/CRTC -- physically dark, while X still reserved its slice of the root
|
|
window. A lock window sized from ``winfo_screenwidth()`` therefore spanned a
|
|
region the user could not see, and the escape UI was rendered into the dark.
|
|
|
|
So: an output is **live** only when it is connected *and* has a mode. Anything
|
|
else is a region no human can look at.
|
|
|
|
Two backends compute the same predicate:
|
|
|
|
* **RandR** via ``python-xlib`` -- authoritative. ``crtc == 0`` or ``mode == 0``
|
|
*is* "connected but modeless".
|
|
* **``xrandr --query``** text -- a re-derivation of the same predicate for
|
|
systems without ``python-xlib``.
|
|
|
|
``python-xlib`` is an optional dependency, loaded on demand through
|
|
:mod:`gatelock._xlib` rather than at module scope. That is deliberate and
|
|
load-bearing: a module-scope ``try/except ImportError`` is resolved at import
|
|
time, which makes the ``except`` arm permanently unreachable for branch
|
|
coverage -- and this is precisely the degradation path that must stay tested.
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
import logging
|
|
import re
|
|
from typing import TYPE_CHECKING
|
|
|
|
from gatelock._output_types import Output, OutputRect, OutputScan
|
|
from gatelock._randr import RandrBackend
|
|
from gatelock._xrandr import parse_xrandr_query, scan_xrandr
|
|
|
|
if TYPE_CHECKING:
|
|
import tkinter as tk
|
|
|
|
# Re-exported after the 250-line split, so `from gatelock._outputs import
|
|
# Output` -- which the tests and sibling modules do -- keeps resolving.
|
|
__all__ = [
|
|
"Output",
|
|
"OutputEnumerator",
|
|
"OutputRect",
|
|
"OutputScan",
|
|
"RandrBackend",
|
|
"enumerate_outputs",
|
|
"parse_xrandr_query",
|
|
"scan_xrandr",
|
|
"tk_fallback_outputs",
|
|
]
|
|
|
|
_logger = logging.getLogger(__name__)
|
|
|
|
|
|
# Output lines start at column 0; mode lines are indented four spaces. That
|
|
# anchor is the whole robustness story -- without it, the mode line
|
|
# " 2560x1440 59.95*+" parses as a geometry and every modeless output
|
|
# silently looks live.
|
|
_OUTPUT_LINE = re.compile(
|
|
r"^(?P<name>\S+)\s+(?P<state>connected|disconnected)\b(?P<rest>.*)$",
|
|
re.MULTILINE,
|
|
)
|
|
|
|
"""Which backend produced a scan. Reported so logs can explain a degradation."""
|
|
|
|
|
|
def tk_fallback_outputs(root: tk.Misc) -> tuple[Output, ...]:
|
|
"""Synthesise one output covering the whole X screen.
|
|
|
|
This is v0.1.1's behaviour, kept as a floor. It cannot tell a dark region
|
|
from a live one, so it is strictly a last resort -- but a lock covering the
|
|
full bounding box beats a lock covering nothing.
|
|
"""
|
|
width = int(root.winfo_screenwidth())
|
|
height = int(root.winfo_screenheight())
|
|
return (
|
|
Output(
|
|
name="tk-screen",
|
|
connected=True,
|
|
rect=OutputRect(x=0, y=0, width=width, height=height),
|
|
),
|
|
)
|
|
|
|
|
|
class OutputEnumerator:
|
|
"""Runs the backend ladder: RandR, then xrandr, then Tk, then nothing."""
|
|
|
|
def __init__(
|
|
self,
|
|
root: tk.Misc | None = None,
|
|
*,
|
|
backend: RandrBackend | None = None,
|
|
) -> None:
|
|
"""Build an enumerator, opening a RandR connection when possible.
|
|
|
|
Args:
|
|
root: A Tk widget used only for the last-resort full-screen
|
|
fallback. Without it, that rung is skipped.
|
|
backend: A pre-opened RandR backend. Defaults to opening one.
|
|
"""
|
|
self._root = root
|
|
self._backend = backend if backend is not None else RandrBackend.create()
|
|
|
|
@property
|
|
def backend(self) -> RandrBackend | None:
|
|
"""The RandR backend, or None when python-xlib is unavailable."""
|
|
return self._backend
|
|
|
|
def close(self) -> None:
|
|
"""Release the RandR connection, if any."""
|
|
if self._backend is not None:
|
|
self._backend.close()
|
|
self._backend = None
|
|
|
|
def scan(self) -> OutputScan:
|
|
"""Enumerate outputs, degrading through the backend ladder."""
|
|
if self._backend is not None:
|
|
outputs = self._backend.scan()
|
|
if outputs is not None:
|
|
return OutputScan(outputs=outputs, source="randr", ok=True)
|
|
outputs = scan_xrandr()
|
|
if outputs is not None:
|
|
return OutputScan(outputs=outputs, source="xrandr", ok=True)
|
|
if self._root is not None:
|
|
return OutputScan(
|
|
outputs=tk_fallback_outputs(self._root), source="tk", ok=True
|
|
)
|
|
_logger.error(
|
|
"every output-enumeration backend failed; reporting a failed scan "
|
|
"so callers leave the lock exactly as it is"
|
|
)
|
|
return OutputScan(outputs=(), source="none", ok=False)
|
|
|
|
|
|
def enumerate_outputs(root: tk.Misc | None = None) -> OutputScan:
|
|
"""Enumerate outputs once, using a throwaway connection.
|
|
|
|
Convenience for one-shot callers (CLI probes, tests). Long-lived callers
|
|
should hold an :class:`OutputEnumerator` so the X connection is reused.
|
|
"""
|
|
enumerator = OutputEnumerator(root)
|
|
try:
|
|
return enumerator.scan()
|
|
finally:
|
|
enumerator.close()
|