"""Hold a logind inhibitor so one power-button press cannot kill the alarm. Item 2 of the hardening plan. Today a short press on the power button runs ``HandlePowerKey=poweroff`` and the alarm is gone in one tap -- less effort than typing a single challenge round. Verified on this host before writing any of this: $ grep PowerKey /etc/systemd/logind.conf #HandlePowerKey=poweroff #HandlePowerKeyLongPress=ignore #PowerKeyIgnoreInhibited=no ``PowerKeyIgnoreInhibited=no`` is the default and is in force, which is exactly what makes a ``--mode=block`` inhibitor suppress the short press. So no ``logind.conf`` edit is needed, and none is made: a drop-in would change the machine permanently, while an inhibitor is scoped to the alarm's lifetime. **What this cannot block, stated plainly:** a ~4 second firmware hold cuts power below the operating system, and so does the PSU switch. Neither is defeatable from userspace. The durable defence against those is the fire-time session record in :mod:`wake_alarm._alarm_session` -- the alarm re-fires on the next boot rather than being escaped -- not this inhibitor. **Why a bounded ``sleep`` and not ``sleep infinity``:** the inhibitor is a child process. If the alarm dies without running ``on_close()`` -- a crash, a SIGKILL -- an orphaned blocker holding ``handle-power-key`` would leave the power button dead until the next reboot, which is a far worse failure than the one being fixed. The child therefore exits on its own after ``INHIBIT_MAX_SECONDS`` even if nobody ever releases it, and a stale one from a previous run is killed at startup -- by pid, via ``/proc``, never by matching a command-line substring (see :func:`_is_our_inhibitor` for why). """ from __future__ import annotations import logging import os import pathlib import shutil import signal import subprocess from wake_alarm._constants import ( INHIBIT_CONFIRM_SECONDS, INHIBIT_MAX_SECONDS, INHIBIT_WHAT, INHIBIT_WHO, INHIBIT_WHY, ) _logger = logging.getLogger(__name__) def _systemd_inhibit_path() -> str | None: """Return the absolute path to systemd-inhibit, or None when absent.""" return shutil.which("systemd-inhibit") def _is_our_inhibitor(pid: str) -> bool: """Report whether *pid* is one of this alarm's inhibitor children. Reads the process's own argv rather than trusting a pattern match. This matters: an earlier version used ``pkill -f "--who=wake-alarm"``, which on a real run matched the *shell that had just typed that pattern* and killed it instead of the inhibitor. Matching a command line by substring is inherently self-matching; asking a specific pid what it is, is not. """ try: argv = pathlib.Path("/proc", pid, "cmdline").read_bytes() except OSError: # The process exited between listing and reading -- it is not stale, # it is simply gone. return False return f"--who={INHIBIT_WHO}".encode() in argv def kill_stale_inhibitors() -> int: """Kill any inhibitor left behind by an earlier alarm process. A blocker that outlived its alarm holds the power button down for every later session, so this runs before a new one is taken rather than trusting that the previous process exited cleanly. Matches on the exact process name and then confirms via ``/proc``, so it can only ever kill a real ``systemd-inhibit`` of ours. Returns: The number of stale processes signalled. """ pgrep = shutil.which("pgrep") if pgrep is None: return 0 try: listed = subprocess.run( [pgrep, "-x", "systemd-inhibit"], capture_output=True, timeout=5, check=False, ) except OSError, subprocess.TimeoutExpired: _logger.warning("Could not check for a stale power-key inhibitor") return 0 killed = 0 for pid in listed.stdout.decode(errors="replace").split(): if not _is_our_inhibitor(pid): continue try: os.kill(int(pid), signal.SIGTERM) except OSError, ValueError: continue killed += 1 if killed: _logger.warning( "Killed %d stale power-key inhibitor(s) left by an earlier alarm", killed, extra={"event": "inhibitor_stale_killed", "count": killed}, ) return killed def take_power_key_inhibitor() -> subprocess.Popen[bytes] | None: """Block the power key for the alarm's lifetime. Returns: The inhibitor child process, or None when systemd-inhibit is missing or could not be started. A missing inhibitor never stops the alarm: being loud without the power key blocked beats not ringing at all. """ inhibit = _systemd_inhibit_path() if inhibit is None: _logger.warning( "systemd-inhibit not on PATH; the power button can still kill " "the alarm in one press", extra={"event": "inhibitor_unavailable"}, ) return None kill_stale_inhibitors() cmd = [ inhibit, f"--what={INHIBIT_WHAT}", "--mode=block", f"--who={INHIBIT_WHO}", f"--why={INHIBIT_WHY}", "sleep", str(int(INHIBIT_MAX_SECONDS)), ] try: # Deliberately not a context manager: this child must outlive the # call and is reaped by release_power_key_inhibitor(). process = subprocess.Popen( cmd, stdout=subprocess.DEVNULL, stderr=subprocess.PIPE, ) except OSError: _logger.warning( "Could not take the power-key inhibitor; the alarm rings unprotected", exc_info=True, extra={"event": "inhibitor_failed"}, ) return None # Popen succeeding only means the *binary* started. logind can still # refuse the inhibit -- polkit denies it outright for a non-interactive # session, which is exactly what a vmbox run turned up: systemd-inhibit # printed "Failed to inhibit: Access denied" and exited 1 while this # function happily reported the power key blocked. Claiming protection # that is not there is worse than reporting none, so wait briefly and # check the child is actually alive. try: process.wait(timeout=INHIBIT_CONFIRM_SECONDS) except subprocess.TimeoutExpired: pass # Still running after the grace period: the inhibit was accepted. else: stderr = b"" if process.stderr is None else process.stderr.read() _logger.warning( "logind refused the power-key inhibitor (rc=%d): %s — the alarm " "rings unprotected", process.returncode, stderr.decode(errors="replace").strip() or "no detail", extra={"event": "inhibitor_refused", "rc": process.returncode}, ) return None _logger.warning( "Power key inhibited for up to %ds (pid %d) — a short press no longer " "kills the alarm; a ~4s firmware hold still cuts power", int(INHIBIT_MAX_SECONDS), process.pid, extra={"event": "inhibitor_taken", "pid": process.pid}, ) return process def release_power_key_inhibitor(process: subprocess.Popen[bytes] | None) -> None: """Release the inhibitor taken by :func:`take_power_key_inhibitor`. Safe to call more than once and safe to call with None, because it runs from ``on_close()``, which itself runs on every exit path. Args: process: The inhibitor child, or None when one was never taken. """ if process is None: return if process.poll() is not None: return process.terminate() try: process.wait(timeout=5) except subprocess.TimeoutExpired: process.kill() _logger.warning("Power-key inhibitor ignored SIGTERM; killed it") _logger.info("Power key released", extra={"event": "inhibitor_released"})