Two spots blocked the alarm on a timer, guessing when the monitor's HDMI sink would be "ready": - _activate_all_outputs polled _list_real_sinks in a loop with time.sleep, waiting up to 20s for ALARM_AUDIO_SINK to appear. - main() slept DISPLAY_WAKE_WAIT_SECONDS (5s) after waking the display before audio setup. Both are gone. Activation now forces every card's output profile on and activates whatever sink is present at that instant; the beep loop's _play_on_all_sinks already re-lists real sinks every cycle, so a slow monitor is swept in the moment it actually enumerates — a real presence check, never a timed guess. main() wakes the display and proceeds immediately; the monitor powers on in parallel. Removes now-dead constants ALARM_AUDIO_CARD, ALARM_AUDIO_PROFILE, ALARM_AUDIO_SINK_WAIT_SECONDS, ALARM_AUDIO_SINK_POLL_SECONDS, DISPLAY_WAKE_WAIT_SECONDS. Activation returns in ~0.26s (was up to 20s); the test suite drops from ~12s to ~2s (two main() tests were each really sleeping 5s). 100% branch coverage retained. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018SJ6HYXhBmYs3SiGBZv1rF
71 lines
2.8 KiB
Python
71 lines
2.8 KiB
Python
"""Constants for the weekend wake alarm system."""
|
|
|
|
from __future__ import annotations
|
|
|
|
from pathlib import Path
|
|
|
|
# Days the wake alarm is active (Python weekday(): Mon=0 ... Sun=6)
|
|
# Every day of the week.
|
|
ALARM_DAYS: frozenset[int] = frozenset({0, 1, 2, 3, 4, 5, 6})
|
|
|
|
# How many hours after shutdown the PC should wake
|
|
WAKE_AFTER_HOURS: int = 8
|
|
|
|
# Minutes after alarm starts within which you must dismiss to earn skip
|
|
DISMISS_WINDOW_MINUTES: int = 30
|
|
|
|
# Hour at which the second (fallback) alarm fires if the first was missed
|
|
FALLBACK_ALARM_HOUR: int = 13
|
|
|
|
# Alarm escalation phase boundaries (minutes from alarm start)
|
|
PHASE_SOFT_END: int = 5
|
|
PHASE_MEDIUM_END: int = 15
|
|
# After PHASE_MEDIUM_END: continuous sine tone until dismiss window closes
|
|
|
|
# Beep intervals per phase (seconds)
|
|
SOFT_BEEP_INTERVAL: float = 10.0
|
|
MEDIUM_BEEP_INTERVAL: float = 5.0
|
|
LOUD_TOGGLE_INTERVAL: float = 2.0
|
|
|
|
# Dismiss challenge: length of the random code
|
|
DISMISS_CODE_LENGTH: int = 10
|
|
# Number of correct code entries required to dismiss the alarm.
|
|
# Requiring more than one round forces the user to stay awake long enough
|
|
# to actually read and type multiple independent codes.
|
|
DISMISS_ROUNDS_REQUIRED: int = 4
|
|
# Seconds the code is visible before being hidden in a flash challenge.
|
|
DISMISS_FLASH_SECONDS: int = 4
|
|
# How often the dismiss code refreshes (seconds)
|
|
DISMISS_CODE_REFRESH_SECONDS: int = 30
|
|
|
|
# State file for wake alarm (HMAC-signed)
|
|
WAKE_STATE_FILE: Path = Path(__file__).resolve().parent / "wake_state.json"
|
|
|
|
# rtcwake binary path
|
|
RTCWAKE_BIN: str = "/usr/sbin/rtcwake"
|
|
|
|
# Preferred alarm audio output (machine-specific, empirically verified).
|
|
# At wake time the Bluetooth speaker is disconnected and PipeWire often has only
|
|
# the auto_null sink, so the alarm activates every card and plays on all sinks.
|
|
# This is the G27Q monitor's built-in HDMI speaker — the one always-present
|
|
# output on this machine — used as the preferred default sink when present.
|
|
ALARM_AUDIO_SINK: str = "alsa_output.pci-0000_01_00.1.hdmi-stereo"
|
|
|
|
# Path to the workout log written by the companion screen_locker package.
|
|
# Dict keyed by YYYY-MM-DD date strings; presence of today's key means the
|
|
# workout was already completed and the alarm should not fire.
|
|
WORKOUT_LOG_FILE: Path = (
|
|
Path.home() / "screen-locker" / "screen_locker" / "workout_log.json"
|
|
)
|
|
|
|
# TP-Link Tapo P110 smart-plug config file (JSON).
|
|
# Create with mode 0600 and these keys: host, email, password.
|
|
# Example contents: a JSON object mapping host -> "192.168.x.x", email ->
|
|
# "tapo@example.com" and password -> "your-password".
|
|
# Missing/invalid file => smart-plug control is skipped silently.
|
|
TAPO_CONFIG_FILE: Path = Path.home() / ".config" / "wake_alarm" / "tapo.json"
|
|
|
|
# Timeout (seconds) for a single Tapo plug operation. Keep short so a
|
|
# missing/unreachable plug never delays the alarm by more than this.
|
|
TAPO_TIMEOUT_SECONDS: float = 5.0
|