Two defences, because one press and one held press are different problems.

**Prevention — _inhibit.py.** A logind block-mode inhibitor on
handle-power-key:shutdown:idle, taken while the alarm is audible and released
in on_close(). Confirmed on the host before writing it that
PowerKeyIgnoreInhibited=no is in force, so no logind.conf drop-in is needed --
and none is added: a drop-in changes the machine permanently, an inhibitor is
scoped to the alarm.

Verified live: the inhibitor appears in `systemd-inhibit --list` as
`wake-alarm ... shutdown:idle:handle-power-key ... block` and disappears on
release.

The child runs `sleep 7200`, never `sleep infinity`. An orphaned block-mode
inhibitor would hold the power button down until reboot -- worse than the bug
being fixed -- so it self-terminates, and a stale one is cleared at startup.

That cleanup was wrong on the first attempt and the host run caught it:
`pkill -f "--who=wake-alarm"` matched the *shell that had just typed the
pattern* and killed it, leaving the real inhibitor alive (`killed 0`, one
inhibitor still listed). Substring matching is inherently self-matching. Now
it lists `pgrep -x systemd-inhibit` and confirms each pid via
/proc/<pid>/cmdline. Re-verified: orphan reaped, exactly one live inhibitor,
zero remaining after release.

**Consequence — _alarm_session.py.** The real gap was that nothing on disk
ever said "ringing, not yet dismissed": wake_state.json is written only on
dismissal, so a hard power-off left no trace and the catch-up window closed
while the machine was down. A signed record is now written at fire time, and
_trigger re-fires on one still marked ringing, ignoring the window.

Deliberately no date field. _state.py keys by UTC and
screen_locker/_wake_state.py mirrors that helper to read the very same file
from another repo, so the UTC basis there is load-bearing. The plan's
_today_str() flip is therefore NOT done -- it would have made any dismissal
between 00:00-02:00 local read as yesterday's in screen-locker and silently
lose an earned workout skip. This record carries only an aware fired_at and
compares elapsed time, so the midnight question never arises.

Age-bounded at 5400 s: an alarm that dies before dismissal leaves a record
nothing ever clears, and unbounded this would restart the alarm every minute
forever.

Two bugs the unit tests could not see, both found by running it:

- A future-stamped record returned None, i.e. "not ringing". But a backward
  clock jump is routine on a machine that hibernates nightly (NTP correcting
  after resume), so that failed *open* on exactly the escape it closes: ring
  on a fast clock, clock corrects, power-off works again. Now clamped to zero
  within a 900 s tolerance and logged.
- _alarm.py derived the correlation id from the alarm's *start* instant. On a
  catch-up or re-fire the PC would write wake-...-0735 while the phone wrote
  wake-...-0700 and the two log streams stop joining. Now
  correlation_id_for_today() derives it from the resolved alarm time, which is
  what _correlation.py always specified.

Every trigger test patched should_refire, so _decide against a real record was
untested -- which is why only the manual run found the first one. There is now
an end-to-end test that writes a real session and asserts the decision.

Splits carried: test_trigger.py 294 -> 197 + test_trigger_main.py,
test_alarm_part2.py 266 -> 170 + test_alarm_timers_flash.py. The inhibitor
handle moved into _AlarmHardware, which also settles pylint's attribute count
and puts it beside the other thing on_close() gives back.

No new suppressions: the one inline pylint disable was redundant, since
consider-using-with is already disabled repo-wide in pyproject.toml.

452 tests pass, 100% branch coverage.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01EckWmyfetYq3Mi8MAnUudh
2026-08-27 20:26:37 +02:00

232 lines
9.0 KiB
Python

"""Tests for _trigger.py — the per-minute check-and-fire tick."""
from __future__ import annotations
from datetime import datetime, timezone
from typing import TYPE_CHECKING
from unittest.mock import patch
import pytest
if TYPE_CHECKING:
from pathlib import Path
from wake_alarm import _alarm_session
from wake_alarm._sync import Alarm
from wake_alarm._trigger import (
_decide,
_fire_window,
_now,
_skip_reason,
)
def _at(hour: int, minute: int) -> datetime:
"""Return a Sunday at the given local wall-clock time, timezone-aware.
Built the same way production does — naive wall clock, then astimezone()
to attach the system offset — so the tests exercise the real comparison
semantics rather than a hand-picked fixed offset.
"""
return datetime(2026, 7, 19, hour, minute, tzinfo=None).astimezone()
@pytest.fixture(autouse=True)
def _ungated() -> None:
"""Open every gate unless a test closes one.
``should_refire`` is stubbed here too: unstubbed it reads the *real*
session record on the host, so a test run started while an alarm was
actually ringing would silently invert half these assertions.
"""
with (
patch("wake_alarm._trigger.was_alarm_dismissed_today", return_value=False),
patch("wake_alarm._trigger.was_workout_logged_today", return_value=False),
patch("wake_alarm._trigger.should_refire", return_value=False),
):
yield
class TestNow:
"""Tests for the _now seam."""
def test_returns_aware_local_time(self) -> None:
"""The clock is timezone-aware and in local time, not UTC."""
now = _now()
assert now.tzinfo is not None
# Local, not UTC: the wall-clock hour must match the system clock's.
assert now.hour == datetime.now(tz=timezone.utc).astimezone().hour
class TestFireWindow:
"""Tests for _fire_window."""
def test_window_starts_at_the_alarm_minute(self) -> None:
"""The fire instant is today at the alarm's H:M, seconds zeroed."""
fire_at, _ = _fire_window(Alarm(6, 45, "remote"), _at(3, 12))
assert fire_at == _at(6, 45)
assert fire_at.second == 0
def test_window_is_the_catchup_length(self) -> None:
"""The window ends TRIGGER_CATCHUP_MINUTES after the alarm."""
fire_at, end = _fire_window(Alarm(6, 45, "remote"), _at(3, 12))
assert (end - fire_at).total_seconds() == 60 * 60
def test_fire_instant_is_aware(self) -> None:
"""The fire instant keeps a timezone, so comparisons are unambiguous."""
fire_at, end = _fire_window(Alarm(6, 45, "remote"), _at(3, 12))
assert fire_at.tzinfo is not None
assert end.tzinfo is not None
def test_offset_is_derived_from_the_target_wall_time(self) -> None:
"""The offset is re-derived, not inherited from *now*.
Guards the DST case: deciding a morning alarm from a tick taken on the
other side of a clock change must not carry *now*'s stale UTC offset.
"""
fire_at, _ = _fire_window(Alarm(6, 45, "remote"), _at(3, 12))
expected = datetime(2026, 7, 19, 6, 45, tzinfo=None).astimezone()
assert fire_at.utcoffset() == expected.utcoffset()
assert fire_at == expected
class TestSkipReason:
"""Tests for the clock-independent gates."""
def test_open_when_nothing_blocks(self) -> None:
"""With every gate open there is no reason to skip."""
assert _skip_reason(_at(7, 0)) is None
def test_not_an_alarm_day(self) -> None:
"""A weekday outside ALARM_DAYS blocks firing."""
with patch("wake_alarm._trigger.ALARM_DAYS", frozenset()):
assert _skip_reason(_at(7, 0)) == "not an alarm day"
def test_already_dismissed(self) -> None:
"""A dismissal recorded today blocks a re-fire."""
with patch(
"wake_alarm._trigger.was_alarm_dismissed_today",
return_value=True,
):
assert _skip_reason(_at(7, 0)) == "alarm already dismissed today"
def test_workout_already_logged(self) -> None:
"""A logged workout means the alarm is no longer needed."""
with patch("wake_alarm._trigger.was_workout_logged_today", return_value=True):
assert _skip_reason(_at(7, 0)) == "workout already logged today"
class TestDecide:
"""Tests for the fire/don't-fire decision."""
def test_before_the_alarm(self) -> None:
"""A tick before the alarm minute does not fire."""
fire, reason = _decide(_at(6, 44), Alarm(6, 45, "remote"))
assert not fire
assert "still ahead" in reason
def test_exactly_on_the_alarm_minute(self) -> None:
"""The alarm minute itself fires."""
fire, _ = _decide(_at(6, 45), Alarm(6, 45, "remote"))
assert fire
def test_within_the_catchup_window(self) -> None:
"""A tick inside the catch-up window still fires (e.g. after resume)."""
fire, _ = _decide(_at(7, 30), Alarm(6, 45, "remote"))
assert fire
def test_at_the_window_edge(self) -> None:
"""The window is half-open: its end instant no longer fires."""
fire, reason = _decide(_at(7, 45), Alarm(6, 45, "remote"))
assert not fire
assert "window closed" in reason
def test_long_after_the_alarm(self) -> None:
"""Hours later, the window is closed."""
fire, reason = _decide(_at(20, 0), Alarm(6, 45, "remote"))
assert not fire
assert "window closed" in reason
def test_gate_beats_the_clock(self) -> None:
"""A closed gate wins even at the exact alarm minute."""
with patch(
"wake_alarm._trigger.was_alarm_dismissed_today",
return_value=True,
):
fire, reason = _decide(_at(6, 45), Alarm(6, 45, "remote"))
assert not fire
assert reason == "alarm already dismissed today"
def test_alarm_moved_earlier_fires_immediately(self) -> None:
"""A phone alarm moved back before now fires on the very next tick."""
fire, _ = _decide(_at(6, 50), Alarm(6, 40, "remote"))
assert fire
class TestRefireOnAnUnfinishedSession:
"""A power-off mid-alarm must not be a way out."""
def test_refires_long_after_the_window_closed(self) -> None:
"""The whole point: the machine may have been off for the window.
Without this, holding the power button ends the alarm for good --
the catch-up window closes while the PC is down and nothing on disk
ever said an alarm was ringing.
"""
with patch("wake_alarm._trigger.should_refire", return_value=True):
fire, reason = _decide(_at(20, 0), Alarm(6, 45, "remote"))
assert fire
assert "cut short" in reason
def test_dismissed_gate_still_beats_a_refire(self) -> None:
"""The ordinary gates are checked first and still win."""
with (
patch("wake_alarm._trigger.should_refire", return_value=True),
patch(
"wake_alarm._trigger.was_alarm_dismissed_today",
return_value=True,
),
):
fire, reason = _decide(_at(20, 0), Alarm(6, 45, "remote"))
assert not fire
assert reason == "alarm already dismissed today"
def test_end_to_end_through_a_real_session_record(
self, tmp_path: Path, monkeypatch: pytest.MonkeyPatch
) -> None:
"""_decide against a real record, with should_refire NOT patched.
Every other test here stubs ``should_refire``, so the wiring between
the record on disk and the decision was untested -- and a manual run
found it broken while the whole suite stayed green. This is the
deterministic version of that manual check.
"""
monkeypatch.setattr(
_alarm_session, "ALARM_SESSION_FILE", tmp_path / "session.json"
)
now = _at(20, 0)
# The record is stamped by the alarm process, which ran at fire time --
# not at this tick. Pin its clock to the same fictional morning as the
# tick, or the two dates are years apart and the age check is
# meaningless.
monkeypatch.setattr(_alarm_session, "_now", lambda: _at(19, 30))
alarm = Alarm(6, 45, "remote")
with patch("wake_alarm._trigger.should_refire", _alarm_session.should_refire):
assert _decide(now, alarm)[0] is False # window closed, no record
_alarm_session.start_session("wake-20260719-0645")
fire, reason = _decide(now, alarm)
assert fire, "a cut-short alarm must ring again"
assert "cut short" in reason
_alarm_session.finish_session()
assert _decide(now, alarm)[0] is False # dismissed stays dismissed
def test_refire_is_asked_about_the_tick_instant(self) -> None:
"""The session's age is measured against the tick, not wall-clock now."""
with patch("wake_alarm._trigger.should_refire") as refire:
refire.return_value = False
_decide(_at(20, 0), Alarm(6, 45, "remote"))
refire.assert_called_once_with(now=_at(20, 0))